STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL
Dump Tests
Short lengths equal to twice their diameter cut from the
rivet bars shall, when cold, withstand without fracture being
compressed to half their length. A dump test shall be made
for each Tensile Test.