Reg. 51
MATERIALS OF CONSTRUCTION
SEAMLESS
FERRITIC
AND AUSTENITIC ALLOY STEEL BOILER, SUPERHEATER AND HEAT
EXCHANGER TUBES
Hydraulic test |
(i)
Each tube shall be tested by the manufacturer and shall withstand a
hydraulic pressure to one and a half time the design pressure
subject to a minimum of 1.00 kgf/mm2, but not greater
than pressure calculated by the following formula:-
P = 2 St/D
where
P = test Pressure
D =
specified out side diameter of the tube
t =
specified wall thickness of the tube
S =
stress
which shall be taken as 40% of the minimum tensile strength at room
temperature for carbon and ferritic steel and 80% of the minimum
yield strength at room temperature for austenitic stainless steel
(ii)
Notwithstanding anything contained in the above clause, the
hydraulic test at the maker's works may be dispensed with, provided
that the tubes are subject to non destructive testing by an
appropriate method like Ultrasonic or Eddy current or Stray Flux
testing.
|